Marshall Electronics

Part # OR434

MFR Part # OR434

The OR-434 Quad 4.3" ORCHID?? rack mount monitor has all the features that customers have asked for and more. More
MSRP: $5749

Availability: Out of stock

$4,759.00

The OR-434 Quad 4.3" ORCHID?? rack mount monitor has all the features that customers have asked for and more. The OR-434 is only 2RU and has 5 user-assignable function keys with a joystick menu system.

The built-in waveform monitor (which includes adjustable White and Black clip level indicators) can be displayed in three different aspect ratios including Full Screen.

The built-in Vectorscope displays in full color and can also be displayed in three different ratios. The Vectorscope has adjustable gain from 1x to 5x.

All screens are color matched at the factory and can be auto-adjusted in the field using an optional color probe system.
The OR-434 will de-embed and display up to 16 channels of audio and allow the user to monitor any two channels at once through the headphone jack or rear line output jack. The 64-segment tri-color bar graph meters have user-adjustable reference levels. The OR-434 comes standard with auto-sensing HD-SDI inputs, re-clocked outputs, and an open modular slot for additional inputs in the future.

  • Real-Time Waveform Monitor
  • Real-Time Color Vectorscope
  • Sixteen 64-segment Tri-color Audio Meters
  • Tri-Color Tally Indicator
  • On-Screen Time Code
  • 7 assignable GPI inputs
  • Adjustable Color Temperature
  • Optional Input Modules
  • Auto-Sensing Front Panel Headphone Jack
  • Auto-Sensing Rear Unbalanced Stereo Output
  • Adjustable Clipping Indicator
  • Precision Gamma Settings
  • Adjustable Color Temperature
  • Variety of Safety Markers
  • HD-SDI / SDI Inputs and Outputs
  • Auto White Balance Calibration -
  • Compatible with Konica Minolta CA-210 Color Analyzer

WAVEFORM MONITOR

The built-in waveform monitor (which includes adjustable White and Black clip level indicators) can be displayed in various aspect ratios, positions, and transparency options. The Waveform Monitor not only monitors luminance, but can also warn the user for out-of-range conditions such as overexposure or "blacker-than-black" errors with fully user-adjustable warning limits.


REAL-TIME COLOR VECTORSCOPE

The built-in Vectorscope allows users to monitor color gamut range in real time. It displays in full color and can also be displayed in various sizes, positions, and transparency options. The Vectorscope has adjustable gain from 1x to 5x.

CLIP GUIDE

The Clip Guide function operates with both the Waveform display and Monochrome/Color picture display. Both the upper and lower Clip Guide levels are user-adjustable in order to accurately display over-and-under exposures during different shooting conditions. For example, the upper Clip Guide limit may be set to 85 IRE and the lower limit to 10 IRE. With these settings, any exposures over the set limit of 85 IRE will display red on both the Waveform and picture (if selected). The same will be true for blacks under 10 IRE.

PRECISION GAMMA

It is important that LCD monitors match the color and gamma characteristics of a CRT monitor. To emulate CRT gamma, the non-linear curves are corrected by software algorithms. This process is complicated because the three non-linear colors (RGB) should be corrected simultaneously. The ORCHID gamma correction overcomes this problem and ensures correct matching between panels and channels.

AUDIO LEVEL METERS

De-embeds and displays up to 16 channels of audio using sixteen 64-segment tri-color Audio Meters with user-adjustable reference levels. The Audio Level Meters provide numerical indicators and headroom levels, as well as peak hold function. Audio Channel Loss Warning prevents errors during monitoring.

FRONT AND REAR PANEL AUDIO OUTPUT

Monitor any two channels at once through the front audio output jack or rear line output jack.

EXTENSIVE MENU SYSTEM

7 user-assignable function keys with Rotomenu system.

WHITE BALANCE

White balance adjustment is essential in order to render colors correctly. To display colors correctly, gray scale should maintain identical color temperature. The white balance for ORCHID monitors defaults to D65 (6500K) so the user does not need to adjust white balance. LCD monitors have color-matching issues because white balance can be affected by a change in luminance level. Our unique color management system solves this problem.

ONE BUTTON COLOR CALIBRATION

The ORCHID operating system includes an Automatic White Balance function that allows a "One Button" calibration procedure when used with a Konica Minolta CA-310 color analyzer. All ORCHID Series LCD panels are calibrated at the factory to ensure color conformity between screens.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Do you have any questions?

Ask a Videoguys adviser about this product. More

Our knowledgeable sales staff is available Mon-Fri, 9am – 5pm ET to help answer any questions you may have regarding system recommendations, compatibility, features and more. Call us at 800-323-2325

Free Tech Support

Shop with confidence with us here to help. More

Videoguys technicians are the best in the industry and are available Mon-Fri, 9am – 5pm ET to help you get your system up and running. We can even help you get in touch with the manufacturer’s Help Desk when needed. Call our tech directly at 516-759-1611

Satisfaction Guaranteed!

30-day money-back or exchange on all purchases. More

We have FREE Tech Support and a 30-day money-back guarantee on all products we sell. If we can't help you get your video editing and production purchase working, you can return it for a refund or we can exchange it for a replacement or apply the value of the product you returned toward the purchase of a different product. If you choose to exchange your purchase, we give you a fresh 30 days to make it work!